MagnaDrive saves Plant Feed Conveyor

plant-feed-1 (1)

Market: Mining/Materials Handling

Site: South Walker Creek Coal

Asset: Plant Feed Conveyor

Power: 45 kW Drive

Output: 800 Tonne/Hour

MagnaDrive Coupling: MGD 16/125

Site Contact: Troy Martin – CHPP Superintendent

1.0 Situation

On the 4th of November 2007, the plant feed conveyor failed to start after the operator attempted to restart operations following a plant stoppage.

When investigating the reason for the failed start it was noted that the motor would run but there was no output from the MagnaDrive coupling to the drive gearbox.

Figure 3 – Feed Chute
Figure 2 – MagnaDrive Coupling

2.0 Findings

An inspection of the belt around the tail end revealed a build up of coal around a wooden surveyor’s peg which had jammed between the bottom of the feed chute and the belt. This was enough resistance to exceed the starting factor of the MagnaDrive coupling, thus preventing the belt from starting.

Figure 4 – Tail End View of Plant Feed Conveyor

Figure 4 – Tail End View of Plant Feed Conveyor

An inspection of the belt around the tail end revealed a build up of coal around a wooden surveyor’s peg which had jammed between the bottom of the feed chute and the belt. This was enough resistance to exceed the starting factor of the MagnaDrive coupling, thus preventing the belt from starting.

3.0 Resulting Action

The belt was isolated and the peg removed, allowing the belt to start and run to full speed.

4.0 Benefit of MagnaDrive Couplings

In a stall or overloaded situation, the starting torque of the belt exceeds the designed service factor of the drive and the MagnaDrive coupling disengages immediately protecting the system from further damage. With a conventional fluid coupling, torque is applied to the belt for some time until the fusible plug or motor thermal overload can disconnect the load.

Low torque transfer during stalled conditions is just one of the many benefits of MagnaDrive couplings.

Revolutionary
Power Transfer

Download the Magnadrive Handbook.

A world-changing industrial technology that saves energy, reduces operation & maintenance costs and improves system reliability.

Other Case Studies

Underground 30,000 Litre Fuel Tank Module

Water Cannon Repair

Breather and Sampling Point Audit - Nth Queensland

10,000 kg Grease Tank Solution

MagnaDrive Coupling Vibration Success

Hose Down Pump

Bearing Skidding

Electric Motor Bearing Defects

Grease Contamination